Radiation Exposure to the Surgeon During Percutaneous Endoscopic Lumbar Discectomy: A Prospective Study

Auteur     Yong Ahn
Auteur     Chang-Ho Kim
Auteur     June Ho Lee
Auteur     Sang-Ho Lee
Auteur     Jin-Sung Kim
Résumé     STRUCTURED ABSTRACT: Study Design. A prospective study.Objective. The purpose of this study was to determine the radiation dose to which the surgeons are exposed during PELD and to calculate the allowable number of cases per year.Summary of Background Data. Transforaminal percutaneous endoscopic lumbar discectomy (PELD) is a minimally invasive technique for soft disc herniation. Minimal invasiveness can be achieved through the use of fluoroscopy and endoscopy. The radiation dose to the surgeon during PELD is unknown.Methods. The occupational radiation dose absorbed by 3 spinal surgeons performing 30 consecutive PELDs (33 levels) over a 3-month period was evaluated. Transforaminal PELDs were performed according to the standard technique. The radiation exposure of the neck, chest, arm, and both hands of the surgeons was measured. Occupational exposure guidelines of National Council on Radiation Protection and Measurements (NCRP) were used to calculate the allowable number of procedures per year.Results. The mean operation time was 49.8 minutes, and the mean fluoroscopy time was 2.5 minutes. No significant correlations were found between operation time and fluoroscopy time. The calculated radiation doses per operated level were as follows: neck, 0.0785 mSv; chest, 0.1718 mSv; right upper arm, 0.0461 mSv; left ring finger, 0.7318 mSv; and right ring finger, 0.6694 mSv. The protective effects of a lead collar and lead apron were demonstrated by the reduction of the radiation dose by 96.9% and 94.2%, respectively. Therefore, with regard to whole-body radiation, 5,379 operations can be performed per year using a lead apron, while only 291 operations can be performed without using a lead apron. Moreover, 1,910 operations can be performed within the occupational exposure limit (OEL) for the eyes (150 mSv), and 683 operations can be performed within the OEL for the hands (500 mSv).Conclusions. Without radiation shielding, a surgeon performing 291 PELDs annually would be exposed to the maximum allowable radiation dose. Given the measurable lifetime radiation hazards to the surgeon, the use of adequate protective equipment is essential to reducing exposure during PELD.
Publication     Spine
Date     Sep 28, 2012

Export bibliographique

Chercher cette référence sur : Google Scholar, Worldcat

doi:10.1097/BRS.0b013e318275ca58

Laisser une réponse

Vous devez etre connectez Pour poster un commentaire