Veille documentaire MTPH

Médecine du travail du personnel hospitalier

An enzyme-mediated assay to quantify inoculation volume delivered by suture needlestick injury: two gloves are better than one.

J Am Coll Surg. 2008 Jan;206(1):113-22. Epub 2007 Sep 17.
An enzyme-mediated assay to quantify inoculation volume delivered by suture needlestick injury: two gloves are better than one.
Lefebvre DR, Strande LF, Hewitt CW.
Division of Surgical Research, Department of Surgery, Robert Wood Johnson Medical School, Cooper University Hospital, Camden, NJ 08103, USA. lefebvre-md@hotmail.com

BACKGROUND: Acquiring a blood-borne disease is a risk of performing operations. Most data about seroconversion are based on hollow-bore needlesticks. Some studies have examined the inoculation volumes of pure blood delivered by suture needles. There is a lack of data about the effect of double-gloving on contaminant transmission in less viscous fluids that are not prone to coagulation. STUDY DESIGN: We used enzymatic colorimetry to quantify the volume of inoculation delivered by a suture needle that was coated with an aqueous contaminant. Substrate color change was measured using a microplate reader. Both cutting and tapered suture needles were tested against five different glove types and differing numbers of glove layers (from zero to three). RESULTS: One glove layer removed 97% of contaminant from tapered needles and 65% from cutting needles, compared with the no-glove control data. Additional glove layers did not significantly improve contaminant removal from tapered needles (p > 0.05). For the cutting needle, 2 glove layers removed 91% of contaminant, which was significantly better than a single glove (p = 0.002). Three glove layers did not afford statistically significant additional protection (p = 0.122). There were no statistically significant differences between glove types (p = 0.41). CONCLUSIONS: With an aqueous needle contaminant, a single glove layer removes contaminant from tapered needles as effectively as multiple glove layers. For cutting needles, double-glove layering offers superior protection. There is no advantage to triple-glove layering. A surgeon should double-glove for maximum safety. Additionally, a surgeon should take advantage of other risk-reduction strategies, such as sharps safety, risk management, and use of sharpless instrumentation when possible.

Export bibliographique

Chercher cette référence sur : Google Scholar, Worldcat

Laisser une réponse